    The main characteristics of China's three-phase four wire system and the harm of

    作者:网站管理员来源:本站原创日期:2014-09-30 12:09:19点击:639

    With the development of high technology especially the development of information technology,the use of computer load, high power electronic equipment based on the nonlinear, three-phase four wire (380V) power grid harmonic pollution problem in the system have become more and more serious, and a direct threat to a variety of new electronic equipment safe use. Therefore,according to the characteristics of three-phase four wire system harmonic and its harm, must do the harmonic management work.

    The harmonic characteristics:

    In the distribution system, harmonic problems compared to other system, harmonic three-phase four line system has the following characteristics: one is the use of electrical equipment has acyclical peak appearing time, harmonic centralized and unified, is usually a large influx of thegrid and launch. Two is due to electric load density of summer, winter two season than during the spring and autumn season two, harmonic content is relatively large injection system. That is,a three-phase four wire distribution system harmonics with seasonal characteristics. The three is the existence of zero sequence component of large system of central line, the harmonicgovernance more difficult.

    The harm caused by:

    A large number of power system harmonics for three-phase four wire exists, its harm obviously.These harmonics if not resolved in a timely manner, first will directly cause the maloperation of relay protection device, affecting the normal work of the power grid. At the same time, but alsoelectric equipment produce great harm, such as will make the power transformer and electric motor to generate some additional loss, reduced work efficiency, increase the harmonic noise,or will affect the normal work of weak current equipment, such as serious interferenceinformation transmission will communication equipment by the harmonic caused by the decline in the quality of information transmission. But for electricity metering unit, this will lead to inaccurate measurement of harmonic power caused by nonlinear loads, measurement of electricity userswill be less than the actual power consumption, while the linear load of users by measurement of electricity will be more than the actual electricity consumption, influence of electric energy metering unit of electricity charge etc..

    Control measures:

    Considering the characteristics of three-phase four wire system harmonic and its harm, using the filter device, carry out the harmonic, is particularly important for the protection of the whole power grid safety is concerned. And filtering device is currently in the W-APF4L type active power filter harmonic pollution is specifically for three-phase four wire system problems indesign, primary and secondary harmonic it produced for commercial office lighting equipment,computer, UPS, elevator, frequency conversion air conditioning and other non line load neutralline, has good filtering effect.